Multimodal Endoscopic Imaging System
Animal Multi-modal Microcatheter Endoscopy GPA-US-10, GUS-2D/3D, GOCT-OCT, GOCT-US-10 Multi-modal (Photoacoustic, Ultrasonic, OCT) in vivo imaging Photoacoustic lateral direction Resolution down to 15μm, OCT lateral direction Resolution down to 8μm, Ultrasound imaging depth up to 30mm 3D Merged Imaging
In vivo imaging; larger depth; detect mucosal lesions and structural lesions.
Multimodal endoscopy
Higher resolution and deeper penetration
Penetration:
The whole biological tube wall
Resolution:
Photoacoustic transverse≤15μm, axial≤65μm
Ultrasound: axial:≤65μm
OCT: transverse≤20μm,axial≤8μm
APPLICATION
●Endoscopic experiments on rats,mice,rabbits and pigs |
●Photoacoustic maximum projection |
●Photoacoustic ultrasound 2D cross-sectional imaging |
●Photoacoustic depth tomography |
● Photoacoustic ultrasound 3D imaging |
● Photoacoustic 3D tunnel perspective |
Ultrasound 2D Imaging |
OCT 2D imaging & OCT 3D imaging |
PRODUCT DESCRIPTION
Photoacoustic multi-modal imaging system combines optical imaging and acoustic imaging techniques to provide high-resolution images of biological tissues at different depths. This technology can be applied to various fields, such as cancer diagnosis, brain imaging, and vascular imaging. The photoacoustic multi-modal imaging system has advantages such as non-invasive, real-time imaging, and low-cost, which makes it a promising tool for medical research and clinical applications.
PRODUCT PARAMETER
There are four models of GCell photoacoustic multi-modal imaging system, please check the parameters as follows
Product Model | GPA-US | GUS | GOCT-US | G0CT |
Imaging modality | PAE&US | US | OCT&US | OCT |
Application | Cardiovascular, digestive system, otolaryngology | Digestive system, ear, nose and throat, urinary system | Cardiovascular, Digestive System, ENT | Cardiovascular, Digestive System, Ear, Nose and Throat, Cranial Nervous System |
Scan angle/ Retraction distance | 360°/80 mm | 360°/40 mm | 360°/ 80 mm | 360°/80 mm |
Scan mode | 2D/3D | 2D/3D | 2D/3D | 2D/3D |
Probe frequency | 12/20 MHz | 12/20 MHz | 12/20 MHz | / |
Imaging speed | 30 fps | 30 fps | 30 fps | 100 fps |
Resolution | (PAE) transverse≤15μm,axial≤65μm (US)axial≤65μm | axial:≤65μm | (OCT) transverse≤20um,axial≤8um (US)axial≤65μm | transverse≤20um, axial≤8 um |
Imaging depth | PAE≥3mm US≥30 mm | ≥30 mm | OCT≥ 3mm US≥30 mm | ≥3mm |
Catheter diameter | 1.0/2.5 mm | 0.7/2.1/2.5 mm | 1.0/2.5 mm | 1.0 mm |
Tube selection | Standard, balloon, guidewire | Standard, balloon, guidewire | Standard, balloon, guidewire | Standard, balloon, guidewire |