Incubator INCUCELL 22

RM14,072.00

PRICE UPON REQUEST

INCUCELL 22

Incubators with Natural Forced Circulation

-Type ECO Line MC000220
-Type EVO Line MC001906
Suitable for safe processing of microbiologic cultures. The INCUCELL??line is characterised by noiseless operation and slow air flow in usable space. The INCUCELL??V line (version with fan) guarantees faster and more precise temperature distribution with small variations. Special fields of use include mainly biologic and microbiologic laboratories. They can be also used for quality tests in pharmaceutical industry and cosmetics, for tests in veterinary medicine and food processing industry.

  • natural, accurate – laboratory incubator
  • chamber volume 22 litres
  • temperature range from 5?C above ambient to 100?C
  • characterized by noiseless operation and fine air flow in the usable space
  • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
  • high-quality and safe drying, heating and tempering of common laboratory materials in laboratory and industrial areas, suitable for safe processing of microbiological cultures
  • standard version with microprocessor control system Fuzzy logic, controls placed on a foil keyboard, process information displayed on LED display
  • wide selection of optional equipment and accessories
  • output for connecting a printer or PC
  • possibility of validation (IQ, OQ)

Specification

Interior of stainless steel material No. 1.4301

volume 22 l
depth 350 mm
width 240 mm
height 300 mm

Tray

standard equipment 2 pcs
storage area (w ? d) 185 ? 265 mm
racks 4 max. number
distance between guide rails 60 mm

Maximal weight of the load*)

inside the oven 25 kg/oven
per tray 10 kg/tray

Door

1 pcs

External dimensions (including door and handle)

depth 560 mm
diameter of the air branch outer / inner 52/49 mm
width 406 mm
610 (N)

Package dimensions (three layers carton)

depth 720 mm
width 500 mm
depth 810 mm

Weight

brut 36 kg
nett 31 kg

Working temperature (beginning of the regulation)

from 5 ?C above ambient temp. to: 100 ?C

Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door

time variation cca (?) 0,4 ?C
space deviation cca (?) 1,1 ?C

Time required to reach 37 ?C with closed air flap and voltage 230 V

70 min

Heat emission at 37 ?C

20 W

Air exchange speed at 37 ?C

4 per hour

Electricity – mains 50/60 Hz

max. power 0,24 kW
nominal voltage 230 V
current 1,1 A
power by stand by 5 W

Download Brochure