VENTICELL 707
Ovens with Forced Circulation
-Type Eco Line MC000215
-Type Evo Line MC001819
Due to a?patented ventilation system the air within the VENTICELL??chamber is ventilated in a?regular spiral way. This?leads to a?homogenous temperature profile throughout the?chamber and short heating times. Operating economy is ensured by higher rate and precision of heating in laboratories. Especially suitable for?very moist goods.
- precise and fast laboratory drying oven
- chamber volume 707 litres
- temperature range from 10?C above ambient to 250/300?C
- forced air circulation system in the chamber guarantees homogeneous temperature distribution in all the processes of drying, heating and sterilization of materials in laboratories
- high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
- higher speed and accuracy of all the tempering procedures ensures economical operation, especially suitable for high humidity materials, for demanding and accurate tests and processes
- wide selection of optional equipment and accessories
- output for connecting a printer or PC
- possibility of validation (IQ, OQ)
Specification
Interior of stainless steel material No. 1.4301
| volume | 707 l |
| depth | 520 mm |
| width | 940 mm |
| height | 1410 mm |
Tray
| standard equipment | 2 pcs |
| storage area (w ? d) | 920 ? 485 mm |
| racks | 19 max. number |
| distance between guide rails | 70 mm |
Maximal weight of the load *)
| inside the oven | 130 kg/oven |
| per tray | 50 kg/tray |
Number of doors
| 2 pcs |
External dimensions (including door and handle)
| depth | 790 mm |
| diameter of the air branch outer/inner | 52/49 mm |
| width | 1160 mm |
| height (inclusive foots – N) | 1910 (K) mm |
Package dimensions (three layers carton)
| depth | 860 mm |
| width | 1230 mm |
| depth | 2085 mm |
Weight
| brut | 240 kg |
| net | 215 kg |
Working temperature **) (beginning of the regulation) – VENTICELL / VENTICELL plus
| from 10 ?C above ambient temp. to | 250 ?C |
Temperature accuracy according to DIN 12 880 T2, at working temperature with closed air flap and door, > 50 ?C
| time variation cca (?) | 0,4 ?C |
| space deviation (?) % cca (?)% of the reached temperature | 2,5 % |
Time required to reach 250 ?C with closed air flap and voltage 230 V
| 64 min |
Heat emission at 250 ?C
| 2550 W |
Air exchange speed at 250 ?C
| 12 cca/hour |
Electricity – mains 50/60 Hz
| max. power input | 4,9 kW |
| nominal voltage | 400/3N V |
| current | 7,8 A |
| stand by | 5 W |