INNO-S (Absorbance, Luminescence & Fluorescence Microplate Reader)

SKU: N/A Categories: , Brand:
General
Detection modes UV-Vis Absorbance
Fluorescence intensity
Luminescence
TRF (Time-resolved fluorescence)
Read methods End point
Kinetic
Spectral scanning
Well-area scanning
Microplate types 6- to 384-well plates
Others labware supported NANO-VC (Microvolume Plate)
INNO-QM (Quality Check Plate)
Temperature control Up to 50 °C ± 0.2°c at 37°c
Shaking Linear & Orbital & Double Orbital with 4 different speeds
Software INNO-XTM (Basic software) & INNO-XSTM (21 CFR part 11 Compliance Software) (Optional)
Certifications IVD
CE Marked
RoHS
ISO 9001 / ISO 13485 / ISO 14001
21 CFR Part 11 Compliance Software
Absorbance
Light source Xenon flash lamp
Detector Photodiode
Wavelength selection Monochromator
Wavelength range 200−999 nm, 1nm increments
Dynamic range 0−4.0 OD
Resolution 0.0001 OD
Pathlength correction Yes
Wavelength accuracy ±2 nm
Wavelength repeatability ±0.2 nm
OD accuracy 0 to 2 OD: ± 1% ± 0.010 OD
OD linearity <1% from 0 to 3.0 OD
Fluorescence Intensity (Filter-based Fluorescence Intensity)
Light source High Power LED
Detector PMT
Wavelength selection Filters
Wavelength range 350~750 nm (Options 850nm)
Dynamic range >6 decades
Sensitivity Top and Bottom : Fluorescein 5pM
(1 fmol/well, 96-well plate)
Luminescence
Wavelength range 200~700 nm (Options 850nm)
Wavelength selection Filters
Detection system Low noise PMT
Sensitivity 10 amol ATP (filter)
Dynamic range >7 decades
Peak wavelength 410 nm
TRF (Time-Resolved Fluorescence)
Light source High Power LED
Detector Filters
Wavelength selection PMT
Physical Characteristics
Connectivity 1 USB, 1 RS232 for external PC control
Power 100-240 Volts AC. 50/60 Hz
Dimensions 408W x 390L x 290H
Weight 18.2 kg
Applicable optional products
Reagent Injector (INNO-D)
  • 2 Syringe pumps
  • 5~1,000μ → 15~1,000μ
  • Minimum prime Vol. 1.1mL, 100μL with back flush
Microvolume Plate (NANO-VC)
  • Nucleic acid and protein quantification with DNA/RNA, Lysozyme, dsDNA, ssDNA, Etc.
  • 2-2.5μL sample capacity with 24 wells
  • 2.5ml cuvette holder
Quality Check Plate (INNO-Q)
  • Absorbance linearity, accuracy, and alignment QC
INNO-S Product line Configurations
The user can select TWO filter sets by default when purchasing the INNO-S(F) model
INNO-S INNO-SA INNO-SF
Absorbance
Fluorescence
Luminescence
TRF
Shaking
Incubation
Dual Reagent injector
INNO product line series configuration chart
INNO INNO-M INNO-SA INNO-SF INNO-S INNO-HD INNO-HM INNO-HML INNO-H
Absorbance (Monochromator) O O O O O O O
Luminescence (Filter) O O O O O
Luminescence (Monochromator) O O
Fluorescence (Filter) O O O O
Fluorescence (Monochromator) O O O
TRF O O O O O O
Dichroic Intensity O O
Fluorescence Polarization O O
Shaking O O O O O O O O O
Incubation O O O O O O O
Dual Injector O O O O O O O
INNO-S Fluorescence Filter List
The user can select TWO filter sets by default when purchasing the INNO-S(F) model
NO Filter NAME EX Wavelength (nm) Part № Bandwidth (EX) EM Wavelength (nm) Bandwidth (EM) Part №
1 CFP 426-450 [438] F-001 24 502-538 [520] 36 F-021
2 GFP 457-487 [472] F-002 30 502-538 [520] 36 F-022
3 FITC 467-498 [482] F-003 31 513-556 [534] 43 F-023
4 YFP 466-497 [481] F-004 31 524-544 [534] 20 F-024
5 CY3 498-523 [510] F-005 25 566-614 [595] 48 F-025
6 TRITC 532-554 [543] F-006 22 576-597 [586] 21 F-026
7 Texas Red 542-582 [562] F-007 40 604-644 [624] 40 F-027
8 mCherry 542-582 [562] F-008 40 603-678 [640] 75 F-028
9 CY5 604-644 [624] F-009 40 672-712 [692] 40 F-029
10 CY5.5 635-675 [655] F-010 40 696-736 [716] 40 F-030
11 DAPI 350-390 [370] F-011 40 417-463 [440] 46 F-031
12 Lucifer Yellow 426-450 [438] F-012 24 513-556 [534] 43 F-032
13 SpectrumGreen 484-504 [494] F-013 20 517-537 [527] 20 F-033
14 Qdot525 415-455 [435] F-014 40 518-533 [525] 15 F-034
15 Qdot605 415-455 [435] F-015 40 598-613 [605] 15 F-035
16 Qdot625 415-455 [435] F-016 40 618-633 [625] 15 F-036
17 Qdot655 415-455 [435] F-017 40 648-663 [655] 15 F-037
18 SpectrumGold 524-544 [534] F-018 20 558-586 [572] 28 F-038
19 SpectrumOrange 532-554 [543] F-019 22 576-596 [586] 20 F-039
20 SpectrumRed 576-596 [586] F-020 20 612-644 [628] 32 F-040
  • ※Highlighted in the color “Yellow” are the two fluorescence filter sets provided at the fluorescence function instrument purchase.
    The user can freely choose any filter in the list, and if there are other wavelengths the user would like to use, please contact the LTEK team.
    Requesting a different set of filters must be made before signing the P.I.
  • ※Numbers in the color “Blue” within the square brackets above indicate the value that the user is required to type in in the software[refer to the Operation manual Pg.25] in case the user has purchased extra filters other than the provided standard filter.
  • ※Also, the above list of filters are the basic filter specifications, and the wavelength specifications of each filter may differ slightly from the specifications shown above.
  • ※Bandwidth values of EX and EM in the list above must also be typed into the EX/EM setting window in the software, along with the EX and EM center value in the color “Blue.”

 

DOWNLOAD BROCHURE